VACEM ELECTRICAL CO., LTD.325603About UsHuanghe Road, Wenzhou Daqiao Industrial Zone, North Baixiang Town, Yueqing City, Zhejiang Province, ChinaVACEM Electrical Co, Ltd (former Yueqing Yuli Vacuum Electric Co., Ltd established in 1994 by the same founder Mr. Zhimin Hu), is located in Yueqing, Zhejiang Province of China. With registered capital of RMB 50 million, technical staff of more than 200, a covered area of 20,000 square meters, and 600 square meters of R & D and testing center. With the belief of  "offering safety, reliable, eco-friendly electrical products to the world", VACEM has a first-class assembly line, testing equipment, and a team of experts who have engaged in vacuum electrical production for years, mainly re

1.14kV Vacuum Contactor for Mining Euipment(VACJ5)
1.14kV Vacuum Contactor for Mining Euipment(VACJ5)
1.14kV Vacuum Contactor for Mining Euipment(VACJ5)
1.14kV Vacuum Contactor for Mining Euipment(VACJ5)
1.14kV Vacuum Contactor for Mining Euipment(VACJ5)
1.14kV Vacuum Contactor for Mining Euipment(VACJ5)
1.14kV Vacuum Contactor for Mining Euipment(VACJ5)
1.14kV Vacuum Contactor for Mining Euipment(VACJ5)
1.14kV Vacuum Contactor for Mining Euipment(VACJ5)
1.14kV Vacuum Contactor for Mining Euipment(VACJ5)
1.14kV Vacuum Contactor for Mining Euipment(VACJ5)
1.14kV Vacuum Contactor for Mining Euipment(VACJ5)
1.14kV Vacuum Contactor for Mining Euipment(VACJ5)

1.14kV Vacuum Contactor for Mining Euipment(VACJ5)

Model NO.
VACJ5-1.14kV/63,80,125,250,400,630A
Delivery
FOB
Minimum order quantity
1 piece
This contactor applies to an electrical power system with AC 50Hz, rated operating voltage 1140V, rated operating current 63 to 630A for remote making and breaking the circuit, as well as frequently starting and controlling the motor.
Quantity:

Basic Info.

Model NO.

VACJ5-63,80,125,250,400,630A/1.14kV

Mechanical Life Time

10,000,000 times

Short-Time Operating Frequency(20s)

2000 times/h

Clearance Between Open Contacts

1.4-1.6mm

Over Travel

0.7-0.9mm

Trademark

VACEM

Origin

Wenzhou, China

1. General description
Using vacuum as the arc-extinguishing medium, the VACJ5 series AC vacuum contactor has the following features:
  Strong arc-extinguishing capability, good withstand voltage performance, large capacity, small size, lightweight, long life, anti-solid skepticism and braking capability, easy repair, safety, and reliability.
  This contactor applies to an electrical power system with AC 50Hz, rated operating voltage 1140V, rated operating current 63 to 630A for remote making and breaking the circuit, as well as frequently starting and controlling the motor. It is particularly suitable for various protection devices to form electromagnetic starters with the advantages of no electric arc leakage and no noise, mainly used in the coal mine, petroleum, iron, and steel, metallurgy, chemical engineering, factories, and mines.


2. Usage range

  • Altitude: no more than 2000 m;

  • Environment temperature: not less than-5℃ or not more than +40℃, average value is no more than+30℃ in 24 hour.

  • Relative humidity: no more than 50% at +40℃, will be more higher at lower temperature;

  • Installation condition: Slant angle between installation surface and vertical surface is no more than 15°.

  • Places without extensive impact and vibration;

  • No gas or dust which can erode metal and damage insulation;

  • Places away from rain and snow;

  • Can operate in polluted environment.


3. Structure and working principles
   This vacuum contactor is composed of vacuum interrupter, base, crutch,electromagnetic operating mechanism, auxiliary switch, rectifier device, switch-off, spring. Supplying 36V, 50Hz power to the contactor, the current changed into DC by rectifier device supplied to electromagnetic coil. Electromagnetic force overcomes closing spring force to drive moving armature actuation, crutch rotating, leading to main contact closing in the vacuum interrupter. Meanwhile, the NC contact of auxiliary switch opened by battledore, and the NO contact closed.When the power is off, electromagnetic actuation force disappeared, and the main contact opened recur to closing spring force, then the contactor at the opening state.


4. Main technical parameter

Item

Unit

63A

80A

125A

160A

250A

400A

630A

Main circuit rated voltage

kV

1.14

Main circuit rated current

A

63

80

125

160

250

400

630

Main circuit making capacity

A/100times

630

800

1250

1600

2500

4000

6300

Main circuit breaking capacity

A/100times

504

640

1000

1280

2000

3200

5040

Main circuit P.F. withstand voltage

kV

10

Electrical life AC3

Ten-thousand times

60

Electrical life AC4

Ten-thousand times

6

Mechanical life time

Ten-thousand times

100

Rated operating frequency AC3

times/h

600

Rated operating frequency AC4

times/h

300

120

Short-time operating frequency(20s)

times/h

2000

Clearance between open contacts

mm

1.5±0.1

1.8±0.1

2.0±0.1

2.2±0.1

Over travel

mm

0.8±0.1

1.0±0.1

1.0±0.1

1.0±0.1

Contact circuit P/F. withstand voltage

kV

2

Closing time

ms

≤100

Opening time

ms

≤80


5. Notice of ordering
The following should be specified when placing an order:

  • Name of the vacuum contactor, type, rated voltage, rated current, as well as control current, control voltage.
  • Quantity
  • Quantity if spare parts needed.