VACEM ELECTRICAL CO., LTD.325603About UsHuanghe Road, Wenzhou Daqiao Industrial Zone, North Baixiang Town, Yueqing City, Zhejiang Province, ChinaVACEM Electrical Co, Ltd (former Yueqing Yuli Vacuum Electric Co., Ltd established in 1994 by the same founder Mr. Zhimin Hu), is located in Yueqing, Zhejiang Province of China. With registered capital of RMB 50 million, technical staff of more than 200, a covered area of 20,000 square meters, and 600 square meters of R & D and testing center. With the belief of  "offering safety, reliable, eco-friendly electrical products to the world", VACEM has a first-class assembly line, testing equipment, and a team of experts who have engaged in vacuum electrical production for years, mainly re

40.5kV Outdoor High Voltage Vacuum Circuit Breaker on Pole (ZW37)
40.5kV Outdoor High Voltage Vacuum Circuit Breaker on Pole (ZW37)

40.5kV Outdoor High Voltage Vacuum Circuit Breaker on Pole (ZW37)

Model NO.
ZW37-40.5kV
Delivery
FOB
Minimum order quantity
1 piece
Quantity:

Basic Info.

Model NO.ZW37-40.5kV
Poles Number3
TypeCircuit Breaker
FunctionConventional Circuit Breaker
CertificationISO9001-2000, CE, CCC
Rated Short Circuit Duration4s
Short-Circuit Current Breaking Times20 times
Mechanical Life10,000 times
Rated Operation Voltage220V (DC;AC)
Rated Operating SequenceO-0.3s-Co-180s-Co
TrademarkVACEM
OriginWenzhou, China

1.General description

ZW37-40.5 type vacuum circuit breaker is outdoor high voltage switch equipment with rated voltage 40.5 kV, tri-phase AC 50 Hz. It mainly used to open and close electric power system load current, overload current and short circuit current. Applicable to substations, industrial and mining enterprises and the urban and rural electric protection and control, especially suitable for frequent operation sites and city network automation distribution network.

2.Normal service conditions

1) Altitude above sea level not exceeding 1000m

2) Air polluted degree: IV

3) Environmental ambient temperature:-35ºC~+40ºC

4) Ice covering thickness: 20mm

5) Monthly average relative humidity not exceeding 90%

Daily average relative humidity not exceeding 95%

6) Wind speed not exceeding 34m/s

7) Installation site: without flammable, explosive or corrosive material, and frequent violent vibration.

8) Earthquake intensity not exceeding 8 degree

3.Main technical parameter

ItemUnitData
Rated voltagekV40.5
Rated insulation level Lightning impulse withstand voltagekV185
Rated insulation level 1min P.F.withstand voltagekV95
Rated currentA630, 1250, 1600, 2000
Rated short-circuit breaking currentkA202531.5
Rated short circuit making current (peak)kA506380
Rated short time withstand currentkA202531.5
Rated peak withstand currentkA506380
Rated short circuit durations4
Rated operating sequenceO-0.3s-CO-180s-CO
Rated short-circuit current breaking timestime20
Mechanical life timetime10000
Rated operation voltageV220(DC, AC)

4.Product show

40.5kv Outdoor High Voltage Vacuum Circuit Breaker on Pole (ZW37)

5.International fairs

40.5kv Outdoor High Voltage Vacuum Circuit Breaker on Pole (ZW37)

Send Message

* clear input
*
Preview on Mobile
X
customer-service Customer Service
skype Skype
wechat WeChat
message Message
go top Top
WeChat Close
qr code
VACEM05
qrcode

Send Message

* clear input
*
Choose language