VACEM ELECTRICAL CO., LTD.325603About UsHuanghe Road, Wenzhou Daqiao Industrial Zone, North Baixiang Town, Yueqing City, Zhejiang Province, ChinaVACEM Electrical Co, Ltd (former Yueqing Yuli Vacuum Electric Co., Ltd established in 1994 by the same founder Mr. Zhimin Hu), is located in Yueqing, Zhejiang Province of China. With registered capital of RMB 50 million, technical staff of more than 200, a covered area of 20,000 square meters, and 600 square meters of R & D and testing center. With the belief of  "offering safety, reliable, eco-friendly electrical products to the world", VACEM has a first-class assembly line, testing equipment, and a team of experts who have engaged in vacuum electrical production for years, mainly re

7.2kV 12kV High Voltage Vacuum Contactor-Fuse Combination Switch for Switchgear (VACFC)
7.2kV 12kV High Voltage Vacuum Contactor-Fuse Combination Switch for Switchgear (VACFC)

7.2kV 12kV High Voltage Vacuum Contactor-Fuse Combination Switch for Switchgear (VACFC)

Model NO.
VACFC
Minimum order quantity
1 piece
Quantity:

Basic Info.

Model NO.VACFC
Mechanical Life50,000 times
Operating Voltage Range75%-100% UeV
Three Phase Non-SimultaneityMax:5ms
Over TravelMin:1.5ms
TrademarkVACEM
OriginWenzhou, China

1.General description

    VACYC permanent magnet AC M.V. vacuum contactor and VACFC series AC M.V. vacuum contactor-fuse combination apparatus(F-C) are three-phase AC indoor middle voltage switch device suitable for AC 50-60Hz and the rated working voltage of main circuit is 7.2kV and 12kV. It has the advantages of flexible function combination, compact and reliable structure, multiple protection functions, long service life and allowed frequent operation. It can be widely used to open and close load circuits such as AC motor and transformer, and can also be used for capacitor reactive power compensation.

    VACFC series combination apparatus adopt modular combination structure, which can be used by single contactor or combined into F-C, and can be fixed or drawout moving type. The drawout type can be used with KYN28A(GZS1) intermediate cabinet with width of 650mm or 800mm, and can be used to replace VSC/P contactor.

    VACYC contactor can be used alone or with other electrical apparatus.

    VACYC permanent magnet AC M.V. vacuum contactor and VACFC series AC M.V. vacuum contactor-fuse combination apparatus meet the requirements of national standards GB/T 14808 and GB/T 11022.

2.Normal using conditions

a. Environment temperature : -5ºC~+40ºC, and average value is no more than +35ºC within 24 hour.

b. Altitude: no more than 1000m.

c. Atmospheric conditions: monthly highest humidity in the most wet month is no more than 90% and monthly average minimum temperature shall be 25ºC. Condensation on the products due to temperature changes shall be considered.

d. Impact vibration: The place is without extensive shaking, impact, and vibration.

e. The place is without explosion hazard, etchant gas and sleet.

f. No rain and snow in places

g. Pollution degree: Three grade

h. Installation type: .III

i. Installation condition: Slant angle between installation surface and vertical surface is no more than 15°.

3.Main technical parameter

ItemUnitVACFC
Rated voltagekV127.2
Rated currentA25-16025-315
Rated breaking currentkA40
Limit breaking capacitykA40(100peak value)
Rated transfer currentkA3.15
1 min rated power frequency withstand voltagekV4232
Lightning impulse withstand voltagekV7560
Power frequency withstand voltage of control circuitkV2
Rated operating voltageV220V(AC/DC optional)
Operating voltage rangeV75%-100% Ue
Maximum operating currentA<7.5
Rated current of auxiliary contactA5
Life electrical AC3thousand times25
Life electrical AC4thousand times10
Life mechanicalthousand times50
Rated operating frequencytimes/h300
Short time operating frequency20s600
Closing timems≤40
Opening timems≤35
Average closing speedm/s≥0.4
Average opening speedm/s≥0.45
Three phase non-simultaneityms≤5
Clearance between open contactsms≥5≥3.5
Over travelmm≥1.5
Main circuit resistanceµΩ≤150 Not including fuse

4.Product show

12kv Vacuum Contactor-Fuse Combination Switch for Switchgear (VACFC)

5.International fairs

12kv Vacuum Contactor-Fuse Combination Switch for Switchgear (VACFC)

Send Message

* clear input
*
Preview on Mobile
X
customer-service Customer Service
skype Skype
wechat WeChat
message Message
go top Top
WeChat Close
qr code
VACEM05
qrcode

Send Message

* clear input
*
Choose language